Hex head screw ISO 4017 / DIN 933

The dimensions of fully threaded hex head screws from M3 to M24 in one table: width across flats per ISO 4017 and the old DIN 933, head height, clearance hole and tap drill. Every size also has its own page with a drawing.

skald

Dimension table

All dimensions in mm

Dimensions of hex head screws ISO 4017 / DIN 933 in mm
SizePitch Ps ISOs DIN 933ka maxHole fineHole mediumTap drill
M3 0.55.55.521.53.23.42.5
M4 0.7772.82.14.34.53.3
M5 0.8883.52.45.35.54.2
M6 11010436.46.65
M8 1.2513135.33.758.496.8
M10 1.516176.44.510.5118.5
M12 1.7518197.55.251313.510.2
M16 224241061717.514
M20 2.5303012.57.5212217.5
M24 33636159252621

s is the width across flats, k the nominal head height, a max = 3 × P. Clearance hole to ISO 273, tap drill = d minus P, rounded to the usual drill size. For M10 and M12 the width across flats differs between ISO 4017 and DIN 933.

The letters

What the dimensions mean

  • d: nominal thread diameter (M8 = 8 mm).
  • P: pitch of the coarse thread.
  • s: width across flats, the distance between two flat sides: the size of your spanner.
  • k: head height.
  • a: maximum length under the head without full thread (3 × P).
  • l: length of the screw, measured without the head.

Questions

Frequently asked questions about hex head screws

01 What is the difference between DIN 933 and ISO 4017?

DIN 933 was withdrawn and replaced by ISO 4017. Thread and head height are the same, but for M10 and M12 the width across flats differs: 17 and 19 mm for DIN 933, 16 and 18 mm for ISO 4017. If both appear in your BOM, they really are different parts.

02 What is the difference between ISO 4017 and ISO 4014?

ISO 4017 (formerly DIN 933) is the hex head screw threaded up to the head. ISO 4014 (formerly DIN 931) has an unthreaded shank under the head.

03 Which lengths are standard?

ISO 4017 lists standard lengths from 2 × d (rounded to a standard length) to 10 × d, with a maximum of 200 mm. For M8 that is 16 to 80 mm.

Checked against

Every dimension on this page was checked on 15 November 2026 against at least two of these sources.

For a critical application, always check the dimensions in the standard or with your supplier.

Is this screw in your BOM twice?